Green Lawn & Garden

FULL SET: RESIDENTIAL TURKU 9KW 240V HOME SPA SAUNA STEAM SHOWER BATH GENERATOR WITH SL-SERIES OUTER DIGITAL CONTROLLER, STEAM HEAD WITH AROMA OIL RESERVOIR, MANUAL DRAIN VALVE, BRASS SAFETY PRESSURE RELIEF AND WATER INLET ELECTROMAGNETIC VALVES

TK90-BRAND NEW 9KW FULLY EQUIPPED RESIDENTIAL STEAM GENERATOR SET INCLUDES: – 9KW 240V TURKU STEAM GENERATOR; – SL-SERIES OUTER DIGITAL CONTROLLER; – STEAM HEAD WITH AROMA OIL RESERVOIR; – MANUAL DRAIN VALVE; – SAFETY PRESSURE RELIEF VALVE; – THERMOSTAT; – CONTROLLER & THERMOSTAT CONNECTION WIRES; – INSTALLATION AND OPERATION GUIDE. *STEAM GENERATOR SIZING 1) Measure length, width & height in feet of the steam/shower or tub/shower: Multiply the Length _____ x Width _____ x Height _____ = Room Volume 2) Adjustments to Room Volume: For Ceramic Tile thin set, acrylic or fiberglass +0% For Ceramic Tile mortar bed or cement board backing +20% For Cast iron tub +20% For Each glass block wall or exterior wall (if freezing is possible) +10% For Natural stones (Marble, granite, slate) +100% 3) Add all figures above to obtain the Total Room Volume required = Total Adjusted Room Volume. AUTO FUNCTIONS: AUTO FILLING: electromagnetic inlet valve will open automatically once the system is started and fill in with water automatically until the water level reaches the maximum level. If the water level is still lower than the minimum required level 10 minutes after the start, it indicates faults of the water supply system, so all heating elements will turn off automatically. AUTO WATER SUPPLEMENTING: if the water level is lower than the required level during operation, auto water supplementing function will be ON and will open the inlet valve. Once the water level reaches the required level, auto water supplementing function turns OFF automatically. If water level is lower than the required level 3 minute after the water supplementing order is given, it indicates faults of the water supply system, all heating elements will turn off.
TK90 STEAM GENERATOR SET INCLUDES: – 9KW 240V TURKU STEAM GENERATOR; – SL-SERIES OUTER DIGITAL CONTROLLER; – STEAM HEAD WITH AROMA OIL RESERVOIR; – MANUAL DRAIN VALVE; – SAFETY PRESSURE RELIEF VALVE; – THERMOSTAT; – CONTROLLER & THERMOSTAT CONNECTION WIRES; – INSTALLATION AND OPERATION GUIDE.
TK90 STEAM GENERATOR SPECIFICATION: ADJUSTED(!) ROOM VOLUME* 335 Cu.Ft./ SL-SERIES OUTER DIGITAL CONTROLLER / SELF-DIAGNOSTIC SYSTEM SUPPORT / AUTO FILLING SUPPORT / AUTO WATER SUPPLEMENTING SUPPORT / NO AUTO DRAIN FUNCTION / BRASS WATER INLET ELECTROMAGNETIC VALVE / MANUAL WATER DRAIN VALVE / 220~240V SINGLE PHASE INPUT POWER / 3 TEFLON HEATING ELEMENTS BY 3KW EACH / 9.2 QUARTS STAINLESS STEEL WATER TANK / 16 Ft CONTROLLER CONNECTION WIRE / 10 Ft. THERMOSTAT CONNECTION WIRE (ft) / CONTROLLER DIMENSION (inch) – 4½×7×1 / UNIT DIMENSION (inch) – 17½×7¼×12¼
AUTO FUNCTIONS:- AUTO FILLING: electromagnetic inlet valve will open automatically once the system is started and fill in with water automatically until the water level reaches the maximum level. If the water level is still lower than the minimum required level 10 minutes after the start, it indicates faults of the water supply system, so all heating elements will turn off automatically.// AUTO WATER SUPPLEMENTING: if the water level is lower than the required level during operation, auto water supplementing function will be ON and will open the inlet valve. Once the water level reaches the required level, auto water supplementing function turns OFF automatically. If water level is lower than the required level 3 minute after the water supplementing order is given, it indicates faults of the water supply system, all heating elements will turn off.
SL-SERIES OUTER DIGITAL CONTROLLER: TEMPERATURE: The LCD will display the temperature measured by the temperature sensor in the range of 43F~140F (6°C-60°C).// TIME DISPLAY: The LCD will display the cycle time. The maximum setting cycle time is 60 minutes while the default setting time is 45 minutes. When no cycle time is set, the LCD will display “CH”.// HEATING: During heating-up process, LED beside “START” button is ON. // HEAT PRESERVATION FUNCTION: During heating-preservation process, LED beside “STOP” button is ON.// TEMPERATURE SETTING INDICATOR: When setting the temperature, the LED button is ON.// TIME SETTING INDICATOR: When setting the time, the LED button is ON. // POWER INDICATOR: When the system is switched ON, the LED at the bottom of the panel is ON.// 01~60 MIN. CONTROLLING TIME RANGE. // 95~131F TEMPERATURE CONTROLLING RANGE.
Generator Sizing: Multiply the Length _____ x Width _____ x Height _____ = Room Volume // Adjustments to Room Volume: For Ceramic Tile mortar bed or cement board backing multiplied by 1.2 / For Cast iron tub multiplied by 1.2 / For Each glass block wall or exterior wall ( if freezing is possible) multiplied by 1.1 / Natural stone tiles* up to 1/2″ is multiplied by 2.00 / Natural stone slabs over 1/2″ is multiplied by 2.25. // Add all figures above to obtain the Total Room Volume required = Total Adjusted Room Volume.

Exit mobile version